R-410A , sold under the trademarked names Puron , Genetron R410A , and AZ-20 , is a near-azeotropic mixture of difluoromethane (CH 2 F 2 , called R-32) and pentafluoroethane (CHF 2 CF 3 , called R-125), which is used as a refrigerant in air conditioning applications. Unlike many haloalkane refrigerants, it does not contribute to ozone depletion, and is therefore becoming more widely used as ozone-depleting refrigerants like R-22 are phased out. However, it has a high global warming potential of 1725 (1725 times the effect of carbon dioxide), similar to that of R-22.
R-410A was invented and patented by Allied Signal (now Honeywell) in 1991. Other producers around the world have been licensed to manufacture and sell R-410A, but Honeywell continues to be the leader in capacity and sales. R-410A was successfully commercialized in the air conditioning segment by a combined effort of three companies. Carrier Corporation, Emerson Climate Technologies, Inc. with Copeland Scroll Compressors (a division of Emerson Electric Company), and Allied Signal worked together in developing the refrigerant for practical use in air conditioners in the United States. R-410A is also the preferred refrigerant for use in residential and commercial air conditioners in Japan and Europe, replacing R-22.
Carrier Corporation was the first company to introduce a R-410A-based residential air conditioning unit in the marketplace in 1996. Carrier holds the trademark Puron and is still the leading supplier of energy efficient R410A air conditioning systems for residential, commercial and chiller applications in the United States today.
R-410A is incompatible with R-22 refrigerant. R-410A is used at much higher operating pressures than R-22 and other newer refrigerants.
Although the United States Environmental Protection Agency has mandated that R-22 (chlorodifluoromethane) along with other hydrochlorofluorocarbons (HCFC's) be phased-out in the U.S., few window-mounted air conditioners are available that use R-410A. All of the largest central air conditioning systems manufacturers in the U.S. offer systems that use R-410A. As an alternative to window-mounted systems, a ductless "split" system is available with R-410A refrigerant, and can be installed with a 3-inch hole through the wall (or window opening).
R-410A designed systems employ thicker walled tubing, and compressors capable of withstanding the higher pressures of R-410A. R-410A systems require different installation and service procedures.
New equipment that uses R-410A will require service personnel to acquire different tools and equipment, safety standards and fundamentals when installing, replacing older split A/C systems, and repairing systems in the field.
HVAC service persons need to understand the safe handling, proper charging, operating characteristics, proper applications, and general use of R-410A refrigerant.
R-410A should only be used in equipment specifically designed and constructed for higher pressure refrigerants. R-410A operates at considerably higher pressures and requires the use of special tanks, gauges and recovery equipment.
R-410A requires training of installation and service personnel in the proper and safe handling of R-410A.
R-410A needs service personnel to understand why all refrigerant flow controls, valves and driers have changed and must be properly applied with newly designed and built compressors.
Many equipment manufacturers are well aware of the concerns and safety issues of working with R-410A and other HFC refrigerants and are requiring installation and service professionals who purchase their R-410A systems to be R-410A Certified.
In order to prepare air conditioning professionals for the challenges presented by R410A, some of the major organizations in the HVACR created the AC&R Safety Coalition.
Air Quality Solutions Improve the air quality inside your home. Improve your home's health by enhancing the quality of the air inside. Carrier humidifiers help you control air ...
Welcome to the future home of: Air Quality Solutions Contact us now at: 717-569-6211. If you see this page, it means that your account is set up and active.
Air Solutions, providing solutions for todays air quality problems
Dynamic AQS provides effective indoor air quality solutions through state-of-the-art electronic air filtration.
Colorado’s first Rheem home comfort design center! Check out working displays of tankless and solar water heaters, Rheem furnaces and air conditioners, geothermal units, boilers ...
Fresh Air’s goal is to provide practical solutions for indoor air quality and moisture intrusion issues experienced by commercial & residential property owners.
Enter a brief description of your site here. ... GOT MOLD? Air Quality Solutions, Inc.... we'll find it...we'll test it...we'll clean it...we'll fix it!
© 2005 Air Quality Solutions, LLC. All rights reserved.
Indoor air quality, duct cleaning and HVAC filtration solutions.
Air Quality Solutions of Rochester Minnesota is a Heating and Ventilation Company that specializes in residential and commercial air duct cleaning and filtration systems.